TITLE 24 ENERGY ANALYSIS REPORT

Ordering a Residential Title 24 Energy Report (CF-1R) through our online platform is a straightforward procedure designed to ensure that your construction project aligns with California's energy efficiency standards.

Navigating through California's stringent energy regulations and requirements is our expertise. Our goal is to streamline the Title 24 calculations and reporting process, guaranteeing seamless compliance with energy standards.

Unlock the power of energy efficiency for your construction projects with HERS Test Near Me. Offering top-notch HERS Testing and Title 24 Energy Analysis Report services, we are your local partner in achieving compliance and sustainability. Get ahead in the construction game by ensuring your project meets California's energy efficiency standards seamlessly. Our certified experts make the process hassle-free, delivering quick and accurate results. Elevate your projects with confidence – choose HERS Test Near Me for a brighter, more energy-efficient future. Contact us today to take the first step towards success!

DUCT LEAKAGE TEST

A duct leakage test is a method used to evaluate the airtightness of a building's duct system. The duct system is the arteries and veins of the (HVAC) system and is responsible for distributing conditioned air throughout the building. A duct leakage test involves pressurizing the duct system with a fan and measuring the amount of air that leaks out of the system. This information can identify areas where the duct system is not adequately sealed, resulting in energy waste and decreased indoor air quality.

The test is typically performed by a certified HVAC technician using specialized equipment, such as a duct blaster or a pressure gauge. The technician will seal all vents and registers in the building, pressurize the duct system with a fan, and measure the amount of air that leaks out of the system. The test results can then be used to determine the airtightness of the duct system and identify areas where improvements can be made to increase energy efficiency and indoor air quality

BLOWER DOOR TEST​

A blower door test is a method used to evaluate the airtightness of a building's envelope, which is the physical barrier that separates the interior of a building from the outside environment. The test uses a large fan to create a pressure differential between the inside and outside of the building, which reveals any leaks in the building envelope. The test is typically performed by a certified building analyst or energy auditor and is an important step in assessing a building's energy efficiency.

Here's how a blower door test works:
1. The building analyst seals all doors and windows in the building except for one, which is used as the entry point for the blower door.
2. The blower door fan is installed in the entry door and turned on, creating a pressure difference between the inside and outside of the building.
3. The building analyst uses specialized equipment, such as a smoke pencil or infrared camera, to locate and quantify the air leaks in the building envelope.
4. The results of the blower door test provide a quantitative measurement of the airtightness of the building envelope, with a lower number indicating a more airtight building.

A blower door test can reveal areas where air leaks are occurring, such as gaps in the building envelope, and can help to identify areas where energy upgrades, such as adding insulation or sealing air leaks, can be made to increase energy efficiency and reduce energy costs.

INDOOR AIR QUALITY

IAQ stands for Indoor Air Quality. In California, the Indoor Air Quality (IAQ) Test is typically used to evaluate the quality of air inside a building or structure.

Exhaust fans play a crucial role in maintaining indoor air quality by removing contaminants and odors from the air. In California, it is often required to have an exhaust fan installed in areas such as kitchens, bathrooms, and laundry rooms, in order to control humidity levels and to remove fumes and other pollutants. The presence and performance of these fans can also be evaluated as part of an IAQ Test.

REFRIGERANT CHARGE VERIFICATION TEST

The refrigerant charge verification test is a procedure used to determine the amount of refrigerant in an air conditioning or refrigeration system. This test is important because having the correct refrigerant charge is critical to the system's performance and efficiency.

The test typically involves the use of specialized equipment, such as a refrigerant scale, refrigerant recovery machine, or refrigerant management system. The equipment is used to measure the amount of refrigerant in the system and to compare it to the manufacturer's specifications. If the refrigerant charge is found to be too low, it can indicate a leak in the system, which can reduce efficiency and cause the system to perform poorly. If the refrigerant charge is found to be too high, it can cause the system to operate inefficiently and can increase energy costs.

The refrigerant charge verification test is typically performed by a trained and licensed HVAC technician. The technician will first recover any refrigerant from the system, and then measure the refrigerant charge using the specialized equipment. Based on the results of the test, the technician can then make recommendations for adjusting the refrigerant charge, repairing leaks, or other steps needed to ensure the system is operating efficiently.

It is important to regularly conduct refrigerant charge verification tests to ensure that your HVAC or refrigeration system is operating at its best. By doing so, you can help to maintain the system's efficiency, prolong its lifespan, and reduce energy costs.

AIRFLOW MEASUREMENT TEST

Airflow measurement tests determine the volume of air moving through a heating, ventilation, and air conditioning (HVAC) system. This information is important for determining the system's performance and efficiency and for identifying areas where improvements can be made.

There are several methods for measuring airflow in HVAC systems, including:
1. Flow hoods: A flow hood is a device placed over a vent or duct and measures the velocity and volume of air moving through the duct.
2. Balancing valves: These can be installed in the ducts to measure air flow at different points in the system.
3. Anemometers: Anemometers are handheld devices that can measure air velocity as it moves through a duct or vent.
4. Pressure gauges: Pressure gauges can be used to measure the pressure drop across a filter or other component in the system, which can be used to calculate the airflow.

The specific method used for airflow measurement will depend on the type of HVAC system and the goals of the test. The tests are typically performed by trained HVAC technicians who use specialized equipment to measure the airflow and determine the system's performance.

WATT-DRAW TEST

A watt-draw test is a procedure used to measure the amount of electrical power being consumed by a device or system. This information can be important for determining the efficiency of the device or system and identifying areas where improvements can be made.

The watt draw test is typically performed using a device called a power meter or a clamp meter, clamped around the electrical supply wire of the device or system being tested. The power meter measures the amount of current flowing through the wire and calculates the power consumption in watts.

The watt draw test can be performed on various devices, including appliances, lighting fixtures, HVAC systems, etc. The test can help determine the energy consumption of a device, comparing the energy efficiency of different devices, and for determining the energy savings from upgrading to more efficient equipment.

FENESTRATION

NEW CONSTRUCTION LIGHTING

SOLAR TESTING

Who Needs a HERS Test or Title 24 Verification?

A HERS (Home Energy Rating System) test or a Title 24 verification is typically required by building codes in some states in the United States for new construction projects or major renovations. A HERS test or a Title 24 verification aims to ensure that the building meets specific energy efficiency standards and regulations.

A HERS test provides an objective measurement of a building's energy performance and identifies areas where improvements can be made to increase energy efficiency. Title 24, on the other hand, is a set of building standards for California that requires all new residential buildings to meet specific energy efficiency standards to reduce energy consumption and greenhouse gas emissions.

In summary, builders, contractors, architects, and homeowners in some states who are planning new construction projects or major renovations may require a HERS test or Title 24 verification.

We help you create smarter, more efficient buildings and homes.

We help you maintain environmental equality and sustainability.

We help builders in increasing profits and reducing energy cost for the state of California.

CONTACT US

Do yo need a Title 24 California energy report for your Home construction project?

CONTACT INFO

CALL: (510) 244-0095
EMAIL: herstestbayarea@gmail.com

HOURS:
Monday - Thursday 8 AM - 8 PM
Friday 8 AM - 12 PM
Saturday - Closed
Sunday 10 AM - 2 PM